Syntax and Commands
AFG3000 Series Arbitrary/Function Generators Reference Manual 3-71
[SOURce[1|2]]:PULSe:WIDTh
This command sets or queries the pulse width for the specified channel.
Pulse Width = Period × Duty Cycle / 100
The pulse width must be less than the period. The setting range is 0.1% to 99.9%
in terms of duty cycle.
AFG3021 and AFG3022: 30 ns to 999 s
AFG3101 and AFG3102: 8 ns to 999 s
AFG3251 and AFG3252: 4 ns to 999 s
Pulse Width Pulse Period – 0.8 × (Leading Edge Time + Trailing Edge Time)
Pulse Width 0.625 × (Leading Edge Time + Trailing Edge Time)
Group
Source
Related Commands
[SOURce[1|2]]:PULSe:DCYCle
Syntax
[SOURce[1|2]]:PULSe:WIDTh {<seconds>|MINimum|MAXimum}
[SOURce[1|2]]:PULSe:WIDTh?{MINimum|MAXimum}
Arguments
<seconds>::=<NRf>[<units>]
where
<NRf> is the pulse width.
<units>::=[ns | µs | ms | s]
Returns
<seconds>
Examples
SOURce1:PULSe:WIDTh 200ns
sets the CH 1 pulse width to 200 ns.