Stream View
3-52 MTM400 MPEG Transport Stream Monitor User Manual
Figure 3-17: Stream view - PCR graph - PCR overall jitter
The Maximum PCR Accuracy Error can be adjusted for all PIDs as follows:
Tests screen Î PCR Tests section Î PCR Overall Jitter (PCR_OJ)
parameter (right-click) Î Max PCR overall jitter.
For individual PIDs:
PIDs screen Î Test: select PCR Jitter Î individual PID parameter (right-
click) Î Max PCR overall jitter.
Right-click on the graph and set the limit for each PID.