Appendix G: Sequence File Text Format
G-2 AWG710&AWG710B Arbitrary Waveform Generator User Manual
For example,
"SINE.WFM", "TRIANGLE.WFM", ...
"GAUSSN.WFM", "", ...
"", "TRIALGLE.WFM", ...
When you do not define a file, NULL string (””) must be placed.
Repeat Count. The <F3> is Repeat Count field.
<F3>:=<Repeat Count>|<Infinity>
<Repeat Count>::= 1 to 65536
<Infinity>::= 0
Enhanced Controls. The <F4> to <F7> are Repeat Count, Wait Trigger, Goto One,
Logic Jump, and Goto <N> respectively.
<F4>::=<Wait Trigger>
<Wait Trigger>::= 1 (On)
0 (Off)
<F5>::=<Goto One>
<Goto One>::= 1 (On)
0 (Off)
<F6>::=<Logic Jump>
<Logic Jump>::= <Line Number> (range: 1 to 8000)
0 (No definition)
-1 (Jump to next line)
-2 (Table Jump)
Note that the Logic Jump setting is effective depending on the jump settings
described in next paragraph.
<F7>::=<Goto N>
<Goto N>::= <Line Number> (Jump to line n, range: 1 to
8000)
0 (Go to next line)