Pagina 1 - 070-7957-01

InstructionsCT-1/CT-2Current Transformer070-7957-01

Pagina 2

4CT-1/CT-2 Current TransformerSpecificationsTable 1 lists the electrical characteristics of the CT-1 and CT-2 Transformerswhen they are connected to t

Pagina 3 - WARRANTY

SpecificationsCT-1/CT-2 Current Transformer5Table 2: General specifications (CT-1 and CT-2) EnvironmentalMeets all Class IV instrument specificationsO

Pagina 4

6CT-1/CT-2 Current TransformerOperationThis section describes how to install the CT-1 or CT-2, discusses low-frequencyprobing, and provides informatio

Pagina 5 - General Safety Summary

OperationCT-1/CT-2 Current Transformer7Low Frequency ResponseThe low-frequency response of the current transformer is proportional to theinductance of

Pagina 6

Operation8CT-1/CT-2 Current TransformerInputcurrentOutputvoltage0.4 ADC0 ADC5 ms/div10 mA/div0.4 ADC0 ADCFigure 7: CT-2 decay characteristics referenc

Pagina 7 - Introduction

CT-1/CT-2 Current Transformer9Replaceable Parts ListThis section contains a list of the replaceable parts for the CT-1 and CT-2. Usethis list to ident

Pagina 8 - Description

Replaceable Parts List10CT-1/CT-2 Current TransformerParts list column descriptionsColumn Column name Description1 Figure & index number Items in

Pagina 9

Replaceable Parts ListCT-1/CT-2 Current Transformer1112 34RecommendedaccessoriesFigure 8: CT-1 and CT-2 accessoriesReplaceable parts list Fig. &in

Pagina 10 - Specifications

Replaceable Parts List12CT-1/CT-2 Current Transformer

Pagina 12 - Operation

Copyright © Tektronix, Inc. All rights reserved.Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this pu

Pagina 14 - Probe Handling

WARRANTYTektronix warrants that the products that it manufactures and sells will be free from defects in materials andworkmanship for a period of one

Pagina 16 - Cross Index

CT-1/CT-2 Current TransformeriGeneral Safety SummaryReview the following safety precautions to avoid injury and prevent damage tothis product or any p

Pagina 17

General Safety SummaryiiCT-1/CT-2 Current Transformer

Pagina 18

CT-1/CT-2 Current Transformer1IntroductionThe CT-1 and CT-2 are high-frequency, bidirectional current probes. The CT-1 isa 1 GHz current probe and the

Pagina 19

2CT-1/CT-2 Current TransformerDescriptionThe CT-1 (1 GHz) and CT-2 (200 MHz) are current probes designed for eitherpermanent or temporary installation

Pagina 20

DescriptionCT-1/CT-2 Current Transformer3100%90%80%70%60%Frequency (Hz)100 k 1 M10 k1 k0.5 ADC0 ADC1 ADCThis response was obtained with the + side of