Setting Alarms and Inserting Errors
3–136
CTS 710 SONET Test Set User Manual
To transmit an alarm:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TRANSMIT ERRORS &
ALARMS
Transmit alarm
set to
None
Line AIS
Line FERF
Path AIS
Path FERF
VT AIS
(Add/Drop/Test
Option Only)
VT FERF
(Add/Drop/Test
Option Only)
DSn Yellow
(Add/Drop/Test
Option Only)
DSn AIS
(Add/Drop/Test
Option Only)
DS3 Idle
(Add/Drop/Test
Option Only)
H Select None to stop transmitting an alarm.
H Select Line AIS to transmit a Line AIS alarm.
H Select Line FERF to transmit a Line FERF alarm.
H Select Path AIS to transmit a Path AIS alarm.
H Select Path FERF to transmit a Path FERF alarm.
H Select VT AIS to transmit a VT AIS alarm.
Setting Alarms and Inserting Errors
3–136
CTS 710 SONET Test Set User Manual
To transmit an alarm:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
TRANSMIT ERRORS &
ALARMS
Transmit alarm
set to
None
Line AIS
Line FERF
Path AIS
Path FERF
VT AIS
(Add/Drop/Test
Option Only)
VT FERF
(Add/Drop/Test
Option Only)
DSn Yellow
(Add/Drop/Test
Option Only)
DSn AIS
(Add/Drop/Test
Option Only)
DS3 Idle
(Add/Drop/Test
Option Only)
H Select None to stop transmitting an alarm.
H Select Line AIS to transmit a Line AIS alarm.
H Select Line FERF to transmit a Line FERF alarm.
H Select Path AIS to transmit a Path AIS alarm.
H Select Path FERF to transmit a Path FERF alarm.
H Select VT AIS to transmit a VT AIS alarm.