Commands Listed in Alphabetical Order
Syntax
POWer:HARMoni
cs:FREQRef
{VOLTage|CURRent|HARMSOURc e|FIXEDFREQuency}
POWer:HARMonics:FREQRef?
Arguments
VOLTage to use a voltage waveform as the frequency reference.
CURRent to use a current waveform as the frequency reference.
HARMSOURce to use a harmonic source waveform as the frequency reference.
FIXEDFREQuency to use a xed frequency value instead of a waveform for the
frequency reference.
Examples
POWER:HARMONICS:FREQREF VOLTage sets voltage source as the frequency
reference.
POWER:HARMONICS:FREQREF? might return :POWER:HARMONICS:FRE QREF
FIXEDFREQ
indicating that the frequency reference is a xed value.
POWer:HARMonics:FREQRef:FIXEDFREQValue
Sets or returns the frequency value when the :FREQRef selection is
FIXEDFREQuency.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:HARMonics:FREQRef:FI XEDFREQValue <NR3>
POWer:HARMonics:FREQRef:FI XEDFREQValue?
Arguments
<NR3> is the xed frequency value.
Examples
POWER:HARMONICS:FREQREF:FI XEDFREQVALUE 100 sets the frequency to
100 Hz.
POWER:HARMONICS:FREQREF:FI XEDFREQVALUE? might return
:POWer:HARMonics:FREQREF:F IXEDFREQVALUE 60 indicating that the xed
frequency value is set to 60 Hz.
MSO4000 and DPO4000 Series Programmer Manual 2-251