POWER:SOA:LIN
EAR:XMAX 700
sets the XMAX value to 700.0000.
POWER:SOA:LINEAR:XMAX ? might return :POWER:S OA:LINear:XMAX
500.0000
indi
cating that the XMAX value for linear plot type is set to 500.0000.
POWer:SOA:LINear:XMIN
Sets or returns the user XMIN value for use in linear SOA calculations.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SOA:LINear:XMIN <NR3>
POWer:SOA:LINear:XMIN?
Arguments
<NR3> is the XMIN value used for linear SOA calculations.
Examples
POWER:SOA:LINEAR:XMIN 2 sets the XMIN value to 2.0000.
POWER:SOA:LINEAR:XMIN ? might return :POWER:S OA:LINear:XMIN
0.0E+0
indicating that the XMIN value for linear plot type is set to 0.0E+0.
POWer:SOA:LINear:YMAX
Sets or returns the user YMAX value for use in linear SOA calculations.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SOA:LINear:YMAX <NR3>
POWer:SOA:LINear:YMAX?
Arguments
<NR3> is the YMAX value used for linear SOA calculations.